Display, sensors, instruments ampifier for flow meters
Display, sensors, instruments ampifier for flow meters
Display, sensors, instruments ampifier for flow meters
Sight Glasses
Flowmeters
Instruments
 BC7 Batch Controller
 RT7 Rate Totaliser
 202i Rate Totaliser
 214i Batcher
 RTB Rate Totaliser
 WFC/5 F to I Converter
 WS5 Scaler
 FC7 F to I Converter
 Sensors & Amplifiers
Downloads
Reference
Site Map
Contacts
Home
Corner image for Display, sensors, instruments ampifier for flow meters

Primary Flowpoints Ltd
Charles Street
Walsall
WS2 9LZ
Contact us now to discuss your instrumentation needs
Contact us now to discuss your instrumentation needs
Tel 01922 650009
Tel +44 1922 650009
Fax 01922 640326
sales@flowpoints.co.uk


Click here for UKAS certificate




Valid HTML 4.01 Transitional
 

MODEL 202 RATE TOTALISER    Click here for 202 Rate Total pdf datasheet

The Model 202 has an LCD display of flowrate and flow total. It takes the output from flowmeters and can be used for local or remote indication.

202Di Rate Totaliser
Quick and easy to set up
Preset to your requirements
Displays rate, total & accumulated total
Optional 4-20mA output
Optional high & low alarms
Highly accurate
Improve product quality
Mounts on the pipe, wall or flowmeter
Battery or DC powered
Waterproof enclosure

 

Application
The 202 Rate Totaliser is designed to display the flow rate and total of your process liquid. You can use it for monitoring, controlling, dispensing, blending or filling of any liqiud when used with turbine, positive displacement and pelton wheel flowmeters. The battery powered version is ideal for areas where a power supply is not available.

Operation
The flowrate and the resettable total are displayed simultaneously. The 202 stores a non resettable total to monitor long term consumption .

Installation and Setup
The rate and totals can be displayed in any engineering units for example litres per minute and barrels. The setup is easy via the front keypad and it can be preset for your requirements.
The 202 can be mounted directly on to your flowmeter, wall mounted or pipe mounted. Cables are installed via waterproof cable glands.

Optional Features
1. Analogue 4-2OmA output
An optional two wire 4-2OmA output is available for transmitting the flow rate to other instruments or control equipment. It is scalable to your requirements and provides a fast response to changes in flowrate. The operating power is drawn from the 4-2OmA loop so that the batteries will last indefinitely.
2. High and low flow alarms
Two flow rate alarms are available for monitoring the flow. The output will trigger when the flow rises above or falls below the high and low alarm levels. This option requires a DC power supply. 3. Linearisation: The accuracy of your system can be improved by programming any flowmeter errors into the 202.

Construction
The instrument is housed in a polycarbonate enclosure that is completely watertight

Specification

Display: LCD which is continuously powered
Resettable total: 7 digits 10mm high resettable from the front panel
Accumulated total: Displayed when the ACCUMTOT (Non resettable) button is pressed
Rate: 4 digits 8.5 mm high
K-factor: The pulses per unit of measurement ( eg pulses/litre) is programmable in the range 0.2 to 29,999
Decimal points: Decimal point positions are selectable for both rate and total
Timebase: Rate can be displayed in units per second minute, hour or day
Frequency range: 0 to 5 kHz
Signal type: Switch settable for sinewave (40mV peak to peak min), open collector, reed switch or pulse.
Batteries: Two lithium battery packs
Battery life: Battery life is dependent on the percentage of time that the instrument is totalising flow.
4-20mA Option: The 4mA and 20mA points are selectable
Accuracy: 0.5% of range
Connection: Two wire
Voltage Drop: 14 V maximum DC Power /
High and Low Flow Alarms Outputs: Two open collector outputs are available for high and low flow alarms. The alarm points are programmable.
Switching power: 200mA. 30V DC
Max DC power input: 12-28 Volt maximum
Physical Temperature: -20oC to 70oC

 Input signals:

1. Pick-off Coil: Sine wave min: 7mV all frequencies
Sine wave max: 35V high frequency 15V low frequency 
2. Preamplifier: Switch levels:
Low level < 8mA, high level > 12mA
Input current max: 50mA 
3. Switch:  Low frequency: dc to 400 Hz
High frequency: dc to 5 kHz 
4.  Voltage Pulse: Switch threshold selectable 2.5V or 1.4V 
5. Proximity Switch threshold 2.2V 
Namur DIN 19234 Switch levels: low < 1mA high > 3mA 
Sensor power supply: 8.2V dc 50mA

 Outputs:

Mounting:  Universal mounting bracket supplied for mounting on wall or panel. 
Mounting options 1.Pipe mounting kit to fix available: the unit on to a pipe.
2. Adaptor for mounting the instrument on to flowmeters.
Protection: Sealed to IP67 Cable entry: By cable glands.
To view the 202 Rate Totaliser pdf data sheet click here:Click here for 202 Rate Total pdf datasheet

To see available data sheets and manuals click here: Download Area