Display, sensors, instruments ampifier for flow meters
Display, sensors, instruments ampifier for flow meters
Display, sensors, instruments ampifier for flow meters
Sight Glasses
Flowmeters
Instruments
 BC7 Batch Controller
 RT7 Rate Totaliser
 202i Rate Totaliser
 214i Batcher
 RTB Rate Totaliser
 WFC/5 F to I Converter
 WS5 Scaler
 FC7 F to I Converter
 Sensors & Amplifiers
Downloads
Reference
Site Map
Contacts
Home
Corner image for Display, sensors, instruments ampifier for flow meters

Primary Flowpoints Ltd
Charles Street
Walsall
WS2 9LZ
Contact us now to discuss your instrumentation needs
Contact us now to discuss your instrumentation needs
Tel 01922 650009
Tel +44 1922 650009
Fax 01922 640326
sales@flowpoints.co.uk


Click here for UKAS certificate




Valid HTML 4.01 Transitional
 

WFC/5 FREQUENCY TO CURRENT CONVERTER    Click here for WFC5 Frequency to Current Converter pdf datasheet

The WFC/5 converts the pulsed output from your flowmeter into an analogue 4-20mA or 0-10V signal.

WFC/5 Frequency To Current Converter
Quick and easy to install
Preset to your requirements
Highly accurate
Monitor consumption and flow rates
Improve your process
Reduce costs and waste
High quality manufacture
High reliability
Immunity to electrical noise

 

Application
The WFC/5 will convert a pulsed flowmeter signal into an analogue signal for instruments such as PLC’s, computers, flow controllers, chart recorders, indicators or moving coil meters.

Installation
The weatherproof, insulated, impact and chemically resistant enclosure allows the instrument to be installed almost anywhere. It can be mounted in a panel or on to a wall via integral holes in the case.

Instrument Function
The WFC/5 will accept any pulsed signal from a flowmeter. It provides you with two analogue outputs of 4 - 20 mA and 0 - 1 mA.
An unscaled (one to one) 5 V TTL pulse can also be used for instruments requiring a square wave pulsed input.
The instrument has a DC power supply for sensors.

Features
Overrun compensation: The controller can automatically compensate for errors caused by slow acting valves and deliver exactly the volume you want.
No flow alarm: If there is a problem and the signal from the flowmeter stops an alarm will be given and the batch will be stopped.
Linearisation: The accuracy of your system can be improved by programming any flowmeter errors into the BC7.
There is a non resettable total to allow you to monitor long term usage.

Construction
The Batch Controller is in a standard 1/4 DIN format to mount in a panel.
The front keypad is a sealed unit which provides you with a splash proof seal that is resistant to most chemicals.

Specification

Construction:  
Protection: IP65
Materials: Polycarbonate with rubber gasket
Mounting: Screws via holes in the base corners
Power input: 110 or 230 V a.c.
Power output: +24V DC  60mA or +8.2V d.c. 12mA and +5V d.c. 30mA
Connections:  PCB mounted screw terminals via a weatherproof cable gland

 Input signals:

Frequency range 0 to 3 kHz
1. Preamplifier: Low level <8mA, high level >11mA, input max: 3.0V 100mA
2. Proximity sensor: Namur DIN 19234, low level <1mA, high level >3mA
3. Pick-off coil: Min.10 mV rms at 100Hz 45mV RMS at 3kHz 
4. Switch closure:  Energising voltage 5V, energising current 10 mA dc
5. Voltage pulse:  Logic low <1V, logic high >2.5V
Input max: 40V
Output: 0-1 mA into16KOhm
  4-20mA or 0-20mA into 800 Ohm
Response time: Approx. 400msec to 60%
Linearity: 0.15% 
Temp coefficient: 0.015%/o
To view the WFC/5 Frequency To Current Converter pdf data sheet click here:Click here for WFC5 Frequency to Current Converter pdf datasheet