Primary Flowpoints
Ltd Charles Street Walsall WS2 9LZ

 Tel 01922
650009 Tel +44 1922 650009 Fax 01922 640326
sales@flowpoints.co.uk
 |
|
WS/5
FLOWMETER SCALER 
The WS/5
converts an unscaled flowmeter pulse into two scaled pulse outputs and an
analogue output of 0-1mA or 0-5mA  Quick and easy to set up Preset to
your requirements Works with all pulsed flowmeters Outputs for
PLCs,computers etc. Highly accurate Monitor consumption and flow
rates High reliability Immunity to electrical noise Weatherproof
enclosure
Application
The WS/5 will convert any unscaled pulsed signal from
your flowmeter into two scaled pulse outputs suitable for connection to
totalisers, PLCs, control systems and computers. The two isolated outputs
can be used for separate systems for example a local display and a computer
input. The analogue output can be used as an economical means of displaying the
flow rate on a separate indicator.
Installation The
weatherproof, insulated, impact and chemical resistant enclosure allows the
instrument to be installed almost anywhere via integral holes in the case.
Instrument Function
The WS/5 will accept any pulsed signal from a flowmeter
and convert it to two scaled pulse outputs and one analogue 0-1mA or 0-5mA
signal. The duration of the pulse output can be adjusted to suit your
rquirements. The WS5 can be supplied with an integral display, either an
analogue dial for flowrate indication or an LCD totaliser. The instrument has a
DC power supply for sensors.
Specification
| Construction: |
|
| Protection: |
IP65 |
| Materials: |
Polycarbonate with rubber gasket |
| Mounting: |
Screws via holes in base corners |
| Power supply: |
110V or 230V a.c. or 12-24V d.c. |
| Power outputs: |
+24V dc unregulated 60 mA |
|
or +8.2V d.c. 12 mA and + 5.0 V d.c. 30 mA |
| Cable connection: |
PCB mounted screw terminals |
| Cable entry: |
Weather proof cable gland |
Input signals:
| Frequency range |
0 to 3kHz |
| 1. Preamplifier: |
Low level <8mA, high level >11mA, input max 3.0V
100mA |
| 2. Proximity sensor |
Namur DIN 19234 Sensitivity low level <1mA high level
>3mA |
| 3. Pick-off coil: |
Min.10 mV rms at 100HZ 45mV rms at 3kHz |
| 4. Switch closure: |
Energising voltage 5V, energising current 10 mA dc |
| 5. Voltage Pulse: |
Logic low <1V, logic high >2.5V, input max 40 V |
Outputs:
| Pulse: |
Two open collector transistors |
| |
Voltage max. 32 V dc load max. 1.0 A 600mW |
| |
Pulse duration 30 , 50 or 100 in msec (selectable) Other
pulse duration's are available |
| Analogue: |
0-1 mA into 5K or 0-5 mA into 1K |
| Linearity: |
+/- 0.5% of reading |
| Optional display |
1) 6 digit LCD counter. The reset button can be inhibited so
that long term usage can be monitored. Approx. 4 year battery life |
| |
2) 96 x 96 mm analogue flow rate indicator. Can be scaled in
any flow units e.g. litre/min, Kg/hour |
To view the WS/5 Flowmeter Scaler pdf data sheet click
here:
To see
available data sheets and manuals click here:
Download Area
Click below to switch to the following
instruments:
|
|